Ticagrelor is an antiplatelet agent which is extensively metabolized in an active metabolite: AR-C124910XX. Ticagrelor antagonizes P2Y12 receptors, but recently, this effect on the central nervous system has been linked to the development of dyspnea. Ticagrelor-related dyspnea has been linked to persistently high plasma concentrations of ticagrelor. Therefore, there is a need to develop a simple, rapid, and sensitive method for simultaneous determination of ticagrelor and its active metabolite in human plasma to further investigate the link between concentrations of ticagrelor, its active metabolite, and side effects in routine practice. We present here a new method of quantifying both molecules, suitable for routine practice, validated according to the latest Food and Drug Administration (FDA) guidelines, with a good accuracy and precision (<15% respectively), except for the lower limit of quantification (<20%). We further describe its successful application to plasma samples for a population pharmacokinetics study. The simplicity and rapidity, the wide range of the calibration curve (2–5000 μg/L for ticagrelor and its metabolite), and high throughput make a broad spectrum of applications possible for our method, which can easily be implemented for research, or in daily routine practice such as therapeutic drug monitoring to prevent overdosage and occurrence of adverse events in patients.